Innotech Genesis V4 System Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Logiciel Innotech Genesis V4 System. Innotech Genesis V4 System User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 115
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
for
Innotech
Genesis
Systems
EDITION: 011100
R
P.O. Box 292 Sunnybank Brisbane Australia. 4109
Phone: 61 7 38411388 Fax: 61 7 38411644
Vue de la page 0
1 2 3 4 5 6 ... 114 115

Résumé du contenu

Page 1 - Innotech

forInnotech GenesisSystemsEDITION: 011100RP.O. Box 292 Sunnybank Brisbane Australia. 4109Phone: 61 7 38411388 Fax: 61 7 38411644

Page 2

Installation Instructions for Innotech Genesis SystemsEdition: 011100viLIST OF TABLESTABLE PAGE2-1. REM Resource Counts. ...

Page 3 - TRADEMARK

Installation Instructions for Innotech Genesis SystemsEdition 011100A-19Figure A-18 shows the preferred connection point for the screen earth. Fittin

Page 4

Installation Instructions for Innotech Genesis SystemsEdition 011100A-20A-4.2.10. Genesis II Isolated Comms. To remove the possibility of damaging th

Page 5 - TABLE OF CONTENTS

Installation Instructions for Innotech Genesis SystemsEdition 011100A-21Figure A-20 shows the same arrangement as that shown in Figure A-19 but with t

Page 6

Installation Instructions for Innotech Genesis SystemsEdition 011100A-22A-4.2.11. Genesis II Comms. Isolated by Repeater. A GENII RPTR RepeaterModule

Page 7

Installation Instructions for Innotech Genesis SystemsEdition 011100A-23If the screen is connected to the SHLD terminal of Port 1 of the Repeater Modu

Page 8 - LIST OF ILLUSTRATIONS

Installation Instructions for Innotech Genesis SystemsEdition 011100A-24A-4.2.12. GENII MPI with Non-Isolated Comms. When using a GENII MPIModem and

Page 9

Installation Instructions for Innotech Genesis SystemsEdition 011100A-25A better solution is to use an MPI that has RS485 isolation ICs and to fit a G

Page 10 - LIST OF TABLES

Installation Instructions for Innotech Genesis SystemsEdition 011100A-26The following procedures should be performed in the order shown before applica

Page 11

Installation Instructions for Innotech Genesis SystemsEdition 011100A-27Figure A-26. Voltage Check, GENII MPI with Isolated/Non-Isolated RS485.Figure

Page 12

Installation Instructions for Innotech Genesis SystemsEdition 011100A-28

Page 13

Installation Instructions for Innotech Genesis SystemsEdition 0111001-1SECTION 1- PRELIMINARY INFORMATION1-1. INTRODUCTION.This manual is intended

Page 14

Installation Instructions for Innotech Genesis SystemsEdition 011100B-1APPENDIX B- DATA SHEETSB-1. INTRODUCTION.This appendix contains information i

Page 15

Installation Instructions for Innotech Genesis SystemsEdition 011100B-2Controllers - ContinuedDS 2.41 IDC4001 Differential ControllerDS 2.51 IPC40hc

Page 16

Installation Instructions for Innotech Genesis SystemsEdition 011100B-3DisplaysDS 4.11 IDD4001 Digital DisplayDS 4.21 IDW400n Wall DisplaysDS 4.22 IDW

Page 17

Installation Instructions for Innotech Genesis SystemsEdition 011100B-4Genesis Hardware - ContinuedDS AO REM GENII AO REM Analogue Output ModuleDS DI

Page 19 - GEN II AI REM

RP.O. Box 292 Sunnybank Brisbane Australia. 4109Phone: 61 7 38411388 Fax: 61 7 38411644Website: http://www.innotech.com.auE-mail:

Page 20 - REMOTE MODULE INTERFACE

Installation Instructions for Innotech Genesis SystemsEdition 0111001-2The purpose of this manual is to provide clear and complete instructions for al

Page 21

Installation Instructions for Innotech Genesis SystemsEdition 0111001-3Individual systems may include hardware items that are not represented in this

Page 22 - D.I.M. D.I.M. D.O.M. D.O.M

Installation Instructions for Innotech Genesis SystemsEdition 0111001-4• Computer-Generated Materials List – the Materials List is also prov

Page 23 - 90 DEGREES

Installation Instructions for Innotech Genesis SystemsEdition 0111002-1SECTION 2- MECHANICAL INSTALLATION2-1. INTRODUCTION.This section of the manual

Page 24

Installation Instructions for Innotech Genesis SystemsEdition 0111002-2plastic base has eight mounting holes; each hole is 4mm in diameter. Not all o

Page 25

Installation Instructions for Innotech Genesis SystemsEdition 0111002-32-2.1.2. Genesis I Digital Controller. The Genesis I Digital Controller is use

Page 26

Installation Instructions for Innotech Genesis SystemsEdition 0111002-4Figure 2-4. Typical Local Expansion Module.2-2.2.2. Remote Expansion Modules

Page 27

Installation Instructions for Innotech Genesis SystemsEdition 0111002-5The system imposes restrictions on the total number and types of REMs that can

Page 29 - GENESIS II DDCINNOTECH

Installation Instructions for Innotech Genesis SystemsEdition 0111002-6Figure 2-6. GENII RMI Remote Module Interface.2-2.2.2.2. Control Station Mo

Page 30

Installation Instructions for Innotech Genesis SystemsEdition 0111002-72-2.2.2.3. Multipoint Module. The GENII MP REM Multipoint Module is aDIN

Page 31

Installation Instructions for Innotech Genesis SystemsEdition 0111002-8Figure 2-8. Typical Enclosure Layout.2-3.1. DIN RAILS. The DIN rail is an in

Page 32

Installation Instructions for Innotech Genesis SystemsEdition 0111002-9Figure 2-9. DIN Rail Dimensions.2-3.2. INSTALLATION GUIDELINES. To ensure co

Page 33

Installation Instructions for Innotech Genesis SystemsEdition 0111002-102-4. DIFFERENCE DATA.This paragraph contains difference data unique to instal

Page 34

Installation Instructions for Innotech Genesis SystemsEdition 0111002-112-4.2. TYPICAL INSTALLATION. Figure 2-11 shows an example of a typic

Page 35

Installation Instructions for Innotech Genesis SystemsEdition 0111002-122-4.3. ADDITIONAL INSTALLATION GUIDELINES. For installation of theGenesis I

Page 36 - GEN II MPC

Installation Instructions for Innotech Genesis SystemsEdition 0111003-1SECTION 3- ELECTRICAL INSTALLATION3-1. INTRODUCTION.This section of the ma

Page 37

Installation Instructions for Innotech Genesis SystemsEdition 0111003-2NOTEIf any data presented in this manual disagrees with information in theappli

Page 38

Installation Instructions for Innotech Genesis SystemsEdition 0111003-3automatically produces a wiring diagram and materials list for the sp

Page 39

© 2000 - All rights reservedPROPRIETARYNo part of the Innotech Genesis II System’s hardware, software, firmware or documentation may bereproduced, tra

Page 40

Installation Instructions for Innotech Genesis SystemsEdition 0111003-43-3.1. GENESIS II DIGITAL CONTROLLER. Figure 3-2 shows theinput/outpu

Page 41 - ANALOGUE INPUT MODULE

Installation Instructions for Innotech Genesis SystemsEdition 0111003-53-3.1.1. Power Input. The Genesis II Digital Controller power requirements are

Page 42 - 3233 343536

Installation Instructions for Innotech Genesis SystemsEdition 0111003-6Table 3-2. Genesis II Digital Controller Digital Inputs.TERMINAL SIGNAL TERMIN

Page 43

Installation Instructions for Innotech Genesis SystemsEdition 0111003-73-3.1.4. Analogue Inputs. The Genesis II Digital Controller’s eight analogue i

Page 44 - DIGITAL OUTPUT MODULE

Installation Instructions for Innotech Genesis SystemsEdition 0111003-83-3.1.5. Analogue Outputs. Sixteen analogue output channels are provided. Eac

Page 45

Installation Instructions for Innotech Genesis SystemsEdition 0111003-9Table 3-5. Genesis II Digital Controller Analogue Outputs.TERMINAL SIGNAL TERMI

Page 46 - −− = Negative Comms Line

Installation Instructions for Innotech Genesis SystemsEdition 0111003-10ribbon cable at the LEM/REM Connector. The individual REMs are connected to t

Page 47

Installation Instructions for Innotech Genesis SystemsEdition 0111003-11NOTEBecause much of the MPC’s input/output connection information issimilar

Page 48 - A1 A2 A3 A4 A5 A6

Installation Instructions for Innotech Genesis SystemsEdition 0111003-12NOTETwo terminals, located between the Digital and Analogue Inputtermi

Page 49

Installation Instructions for Innotech Genesis SystemsEdition 0111003-13Figure 3-5. Genesis I Digital Controller Input/Output Terminals.Table 3-7. Ge

Page 51

Installation Instructions for Innotech Genesis SystemsEdition 0111003-14• GENII AIM AISC – Analogue Input Module AISC• GENII DO5 – D05 Digital AISC•

Page 52

Installation Instructions for Innotech Genesis SystemsEdition 0111003-15Each type of LEM provides four additional signal channels for the controller.

Page 53 - DI 1 DI 2 DI 3 DI 4 DI 5

Installation Instructions for Innotech Genesis SystemsEdition 0111003-16or to terminate cable screens. Terminal 2 is the GND terminal for the analogu

Page 54 - • SHLD = Comms cable shield

Installation Instructions for Innotech Genesis SystemsEdition 0111003-17CAUTIONLOOP POWERED 4-20MA INPUTS MUST NOT BE USED WITHTHE GEN II ANALOGUE INP

Page 55 - COMMS DIGITAL INPUTS SENSOR

Installation Instructions for Innotech Genesis SystemsEdition 0111003-183-4.1.3. DOM Digital Output Modules. Each DOM (Figure 3-8) provides a

Page 56 - COMMISSIONING

Installation Instructions for Innotech Genesis SystemsEdition 0111003-193-4.2. REMOTE EXPANSION MODULES. The following paragraphs containwirin

Page 57

Installation Instructions for Innotech Genesis SystemsEdition 0111003-203-4.2.2. RS485 Comms Connections. The RS485 Comms link between the RMIand the

Page 58

Installation Instructions for Innotech Genesis SystemsEdition 0111003-21Figure 3-10 shows how to connect a two-cable Comms network to a module. If th

Page 59

Installation Instructions for Innotech Genesis SystemsEdition 0111003-22Figure 3-11. RMI Remote Module Interface.3-4.2.4. AI REM Analogue Input M

Page 60 - 4-1.2.2.1

Installation Instructions for Innotech Genesis SystemsEdition 0111003-23

Page 61 - JUMPER WIRE

Installation Instructions for Innotech Genesis SystemsEdition: 011100iTABLE OF CONTENTSSECTION/PARAGRAPH PAGESECTION 1-PRELIMINARY INFORMATION ...

Page 62 - 4-1.2.2.2

Installation Instructions for Innotech Genesis SystemsEdition 0111003-24Table 3-12. AI REM Analogue Input Signal Connections.TERMINAL SIGNAL TERMINAL

Page 63 - GENII DI REM

Installation Instructions for Innotech Genesis SystemsEdition 0111003-253-4.2.6. IDI REM Opto Isolated Digital Input Module. The IDI REMpro

Page 64 - 4-1.2.3

Installation Instructions for Innotech Genesis SystemsEdition 0111003-26Table 3-16. DO REM Relay Output Signal Connections.TERMINAL SIGNAL TERMINAL SI

Page 65 - EXTERNAL

Installation Instructions for Innotech Genesis SystemsEdition 0111003-27Figure 3-15. MP REM Multipoint Module.POWER and DIGITAL OUTPUTS terminals

Page 66

Installation Instructions for Innotech Genesis SystemsEdition 0111003-28The group of five terminals at the lower left of the module serves two separat

Page 67 - 4-1.2.4

Installation Instructions for Innotech Genesis SystemsEdition 0111003-29Figure 3-16. MP REM, Digital Input Wiring.SHLD +DI#1-+DI#2-+DI#3-+DI#4-TH1 TH

Page 68

Installation Instructions for Innotech Genesis SystemsEdition 0111004-1SECTION4- COMMISSIONING4-1. INTRODUCTION.The commissioning phase begins upon co

Page 69 - CONDITIONERS

Installation Instructions for Innotech Genesis SystemsEdition 0111004-2 Make sure all units are located to provide safe access for operation and maint

Page 70 - 4-1.2.4.2

Installation Instructions for Innotech Genesis SystemsEdition 0111004-3Table 4-1. Genesis System Power Inputs.OPERATING VOLTAGEUNIT24Vac10%24Vdc10%24

Page 71

Installation Instructions for Innotech Genesis SystemsEdition 0111004-4Check 24Vac and 24Vdc inputs as follows:a. Ensure power to the unit is turned o

Page 72 - 4-1.2.5

Installation Instructions for Innotech Genesis SystemsEdition: 011100iiTABLE OF CONTENTS – (Continued)SECTION/PARAGRAPH PAGE3-3.2. GENESIS II MID POIN

Page 73

Installation Instructions for Innotech Genesis SystemsEdition 0111004-54-1.2.2. Checking Digital Input Wiring. Digital input wiring to controllers a

Page 74 - 4-1.4.2

Installation Instructions for Innotech Genesis SystemsEdition 0111004-6Figure 4-2. Checking Digital Input Wiring.NOTEThe following procedures assu

Page 75 - 4-1.4.3

Installation Instructions for Innotech Genesis SystemsEdition 0111004-7d.Ensure the voltmeter reads Zero Volts. If the reading is other than Zero Vo

Page 76 - INNOTECH

Installation Instructions for Innotech Genesis SystemsEdition 0111004-8g.Observe the voltmeter. It should indicate 0Vdc with the input switch closed.

Page 77

Installation Instructions for Innotech Genesis SystemsEdition 0111004-9WARNINGDIGITAL OUTPUTS ARE CONTROLLED BY RELAYS WITHINTHE ASSOCIATED GENESI

Page 78 - 4-1.7.1

Installation Instructions for Innotech Genesis SystemsEdition 0111004-10The output circuits are then checked for the opposite condition. For circuits

Page 79 - 4-1.7.2.1

Installation Instructions for Innotech Genesis SystemsEdition 0111004-11CAUTIONBEFORE PERFORMING THE FOLLOWING PROCEDURES,ENSURE THERE ARE NO SHOR

Page 80

Installation Instructions for Innotech Genesis SystemsEdition 0111004-12t.Remove operating power from the output device.u.Remove the jumper wire conne

Page 81

Installation Instructions for Innotech Genesis SystemsEdition 0111004-13Table 4-3. Analogue Input Checks.AISCMODELINPUTTYPEPARAMETERMEASUREDEXPECTEDV

Page 82

Installation Instructions for Innotech Genesis SystemsEdition 0111004-14Figure 4-5. AISC Locations.When an Analogue Input Module LEM is used, the out

Page 83

Installation Instructions for Innotech Genesis SystemsEdition: 011100iiiTABLE OF CONTENTS – (Continued)SECTION/PARAGRAPH PAGE4-1.2.4.1. Voltage Checks

Page 84 - Example B

Installation Instructions for Innotech Genesis SystemsEdition 0111004-15Procedures for performing voltage checks are:CAUTIONENSURE THAT NO AC VOLT

Page 85 - Zone BZone A

Installation Instructions for Innotech Genesis SystemsEdition 0111004-16CURRENTACROSS 500I050 – 5mA0 – 2.5VdcI204 – 20mA2 – 10VdcTD10 – 250A0 – 0.125V

Page 86 - 1 234- - - -29 30 31 32

Installation Instructions for Innotech Genesis SystemsEdition 0111004-174-1.2.4.3. Resistance Checks. This paragraph contains procedures for checking

Page 87

Installation Instructions for Innotech Genesis SystemsEdition 0111004-18NOTEThe analogue output circuit resistance for the Genesis I and II DigitalCon

Page 88

Installation Instructions for Innotech Genesis SystemsEdition 0111004-19Table 4-4. Units Requiring Jumper Settings.JUMPER TYPE:ADDRESSEND-OF-CABLEANA

Page 89

Installation Instructions for Innotech Genesis SystemsEdition 0111004-20Figure 4-6. Address Jumpers, Typical Settings.Figure 4-7. End-of-Cable Jumpe

Page 90 - BOTTOM EDGE OF BOTTOM BOARD

Installation Instructions for Innotech Genesis SystemsEdition 0111004-21The computer-generated wiring diagram shows the location and jumper position f

Page 91

Installation Instructions for Innotech Genesis SystemsEdition 0111004-224-1.6. LOAD SOFTWARE AND CONFIGURE THE CONTROLLER(S).The Innotech configurati

Page 92

Installation Instructions for Innotech Genesis SystemsEdition 0111004-23c.Turn on the computer and allow it to boot-up. Turn on the controller’s oper

Page 93

Installation Instructions for Innotech Genesis SystemsEdition 0111004-24sensor or switch can be simulated to determine how the rest of the configurati

Page 94

Installation Instructions for Innotech Genesis SystemsEdition: 011100ivTABLE OF CONTENTS – (Continued)SECTION/PARAGRAPH PAGEA-4.2.9. Genesis II Non-Is

Page 95

Installation Instructions for Innotech Genesis SystemsEdition 0111004-25CAUTIONOPERATION OF THE GEN2MON SOFTWARE IN THESIMULATION MODE PRESENT

Page 96

Installation Instructions for Innotech Genesis SystemsEdition 0111004-26f. Disconnect the RS232 cable between the PC and the controller.g.Repeat proc

Page 97

Installation Instructions for Innotech Genesis SystemsEdition 011100A-1APPENDIX A- NETWORK INSTALLATIONA-1. OVERVIEW.The Innotech Genesis group

Page 98

Installation Instructions for Innotech Genesis SystemsEdition 011100A-2A-2.3. GENII RS485I ISOLATED RS485 COMMS. The GENII RS485I IsolatedRS485 Comm

Page 99

Installation Instructions for Innotech Genesis SystemsEdition 011100A-3A-4.1. GENESIS II COMMS WIRING TOPOLOGY. Bus topology is producedby connectin

Page 100 - Screen1 2

Installation Instructions for Innotech Genesis SystemsEdition 011100A-4A-4.1.2. Linking Networks in Different Locations. When linking networks indif

Page 101 - Isolated

Installation Instructions for Innotech Genesis SystemsEdition 011100A-5A-4.2. GENESIS COMMS WIRING CONSIDERATIONS. The maximumnumber of nodes

Page 102

Installation Instructions for Innotech Genesis SystemsEdition 011100A-6Figure A-6. Genesis Comms Wiring Connections.Screen Connected to TerminalScree

Page 103

Installation Instructions for Innotech Genesis SystemsEdition 011100A-7A-4.2.2. Genesis I Connections. The Common connection provided by the trackso

Page 104

Installation Instructions for Innotech Genesis SystemsEdition 011100A-8A-4.2.3. Genesis II Connections. The Common connection provided by the tracks

Page 105

Installation Instructions for Innotech Genesis SystemsEdition: 011100vLIST OF ILLUSTRATIONS – (Continued)FIGURE PAGE4-1. Checking Power Input. ...

Page 106

Installation Instructions for Innotech Genesis SystemsEdition 011100A-9A-4.2.4. GENII POLY SWITCH Board. The GENII POLY SWITCH RS485Protection Plug

Page 107 - 89 90 91 92 93

Installation Instructions for Innotech Genesis SystemsEdition 011100A-10A-4.2.5. GENII 485I Isolated RS485 Comms Card. The GENII 485I IsolatedRS485

Page 108 - Comms Cables for Port 1

Installation Instructions for Innotech Genesis SystemsEdition 011100A-11A-4.2.6. GENII RPTR Repeater Module. The Repeater Module (Figure A-11)can be

Page 109 - Edition 011100

Installation Instructions for Innotech Genesis SystemsEdition 011100A-12WARNINGIF THE EARTH TERMINAL IS NOT CONNECTED TO THEELECTRICAL EARTH,

Page 110 - APPENDIX B- DATA SHEETS

Installation Instructions for Innotech Genesis SystemsEdition 011100A-13Figure A-12. GENII MPI Modem and Printer Interface.A-4.2.8. Genesis I Non-Is

Page 111

Installation Instructions for Innotech Genesis SystemsEdition 011100A-14Figure A-13. Genesis I Non-Isolated Comms.A-4.2.9. Genesis II Non-Isolated C

Page 112

Installation Instructions for Innotech Genesis SystemsEdition 011100A-15The Genesis II has links that allow the screen connection of the RS485 Comms c

Page 113

Installation Instructions for Innotech Genesis SystemsEdition 011100A-16WARNINGPARAGRAPHS A-4.2.9.1 AND A-4.2.9.2, BELOW, AND THEIRREFERENCED F

Page 114

Installation Instructions for Innotech Genesis SystemsEdition 011100A-17Figure A-16 shows a wiring arrangement that is slightly better. The earthing

Page 115

Installation Instructions for Innotech Genesis SystemsEdition 011100A-18A-4.2.9.2. Use of GENII POLY SWITCH Boards. The GENII Poly SwitchBoards prov

Commentaires sur ces manuels

Pas de commentaire